EXP-24 Electronic Positioner

EXP-24 Electronic Positioner

Stand-Alone Accurate, Adaptable, Electronic Positioner

  • Fully capable 24 VDC motion controller
  • Drives most 3-phase linear and rotary actuators
  • Complies with CSA and EU ATEX Directive
  • Conforms to 2014/34/EU for explosion-proof applications
Find a Distributor

The EXP Series positioner is an obsolete product and no longer available for sale.

Accurate, Adaptable, Electronic Positioner

The EXP-24 electronic positioner is designed to be used with Exlar® EL100 actuators in high temperature, hazardous locations. Also it is well suited to drive most 3-phase linear actuators and rotary motors. This accurate and adaptable positioner features a fully capable 24 VDC motion controller and brushless servo motor amplifier. Its rugged design and protective housing conform to CSA and the EU ATEX Directive 2014/34/EU for explosion-proof applications.

Engineered for Hazardous Environments

Capable of powering most resolver feedback brushless motors, the EXP-24 is one of the only servo drive solutions on the market that is engineered for use in hazardous environments. This fully electronic positioner is ideal for process control applications, such as engine test stands, fuel skids, oil platforms, paint booths, and many other applications in harsh or potentially explosive atmospheres. Additionally it has the ability to accurately position valves and dampers by following an analog input signal. For consistency, accuracy, and durability, the EXP-24 is ready to perform. Read about about certification for hazardous locations.

Other Advantages

  • Complies with CSA Class I Division 1 classification systems
  • Conforms with ATEX Directive (LCIE 09 ATEX 3057 X)
  • User friendly configuration software for fast, accurate, dependable positioning
  • Features convenient conduit entry ports and easily accessible internal terminal strips
  • Drives most 3-phase linear actuators and rotary motors
  • Multiple motion modes available for a wide range of applications
  • IP66 environmental sealing standard

 

Quick Data

Model: EXP-24
Input Voltage: 18 to 32 VDC
Input Current, DC: 30 A peak, 25 A continuous
Output Current, 3Ø: 30 A (21 ARMS) peak, 25 A (18 ARMS) continuous
Environmental: Operating temperature range of -29° to 82° C
Standards/Ratings: IP66 standard, NEMA Type 4; CSA Class I, Division 1, Groups B, C, D, and T5; EU Compliance 2014/34/EU for use in potentially explosive atmospheres (ATEX) Ex d II B T5

Configuration Options

EXP-24 Configuration Options

AAA = Controller Type
BB = Nominal Input Voltage
CC = Nominal Output Current
D = Vent and Drain Selection
EEE = Customer Code
FFFFF = Part Number Is Unique to Model Configuration

Standard Features

EXP-24 Standard Features
  • CSA Class 1, Division 1 compliant
  • ATEX Directive (LCIE 09 ATEX 3057 X) compliant
  • Intuitive configuration software
  • Convenient conduit entry ports
  • Easily accessible internal terminal strips
  • IP66, NEMA Type 4 enclosure

* Some options are not available with every configuration. For options or specials not listed above or for extended temperature operation, please consult Exlar Applications Engineering.

IP Ratings for Exlar Actuators

EXP-24 Electronic Positioner

Performance Specifications
EXP24 PERFORMACE SPECIFICATIONS
 Printable View
 
Input Voltage 18 to 32 VDC
Input Current, DC 30 A Peak, 25 A Continuous
Output Current, 3A 30 A (21 ARMS) Peak, 25 A (18 ARMS) Continuous
Digital Inputs 2 - Isolated, 18 to 32 VDC
Digital Outputs 2 - Isolated, 18 to 32 VDC, 250mA Continuous
Analog Input 1 - Non-isolated, 4 to 20maA, 500 Ω Input Impedance
Analog Output 2 - Isolated, 4 to 20mA, 200 Ω to 500 Ω Driving Capability
Serial Interface Isolated RS-485, Modbus Protocol, Max. Baud Rate 38.4k
Commutation Sinusoidal, Space Vector PWM, 10 kHz
Position Feedback Resolver
Environmental -29 to 82°C Operating Temperature Range
Enclosure IP66, NEMA Type 4
N.A. Certifications CSA Class I Division 1 Groups B, C, D, T5
E.U. Compliance 94/9/EC Potentially Explosive Atmospheres (ATEX) Ex d II B, T5
EMC Immunity: EN 61000-6-2: 2005, Emission: EN 61000-6-4: 2007
Approx. Weight 33 lbs (15 kg)

Resources

See All Resource Material for the Tritex II and other products in our Resource Library

Login

Please log in or register to see the models and drawings.

Register

If you do not have a login, please proceed to the registration page

Register

If you currently have an Exlar website account and would like to delete it, please contact

CHA_Info@curtiss-wright.com

Privacy Notice

By giving us your contact information, you are giving consent to Curtiss-Wright / Exlar Automation to store your data and follow-up with you via email or phone.

At Curtiss-Wright, we promise to treat your data with respect and only share it with our representatives and distributors for the purpose outlined on the form. You can remove your request or information at any time by reaching out to our team at cha_info@curtisswright.com.

For further information on how we protect your information, please refer to our Privacy Notice.


Stay up to date

Get the latest Exlar product updates delivered directly to your inbox

You can change your mind at any time by clicking the unsubscribe link in the footer of any email you receive from us, or by contacting us at cha_info@curtisswright.com



Country *:
 Security code
 How we use this information